您知道防火卷簾的正確控制方法嗎?
煙霧探測器與煙霧探測器的結(jié)合,從控制方法上保證了防火卷簾迫降的可靠性。在多個(gè)防火卷簾處,一些設(shè)計(jì)單位在每個(gè)卷簾處設(shè)置煙霧探測器或溫度探測器。當(dāng)探測器移動(dòng)時(shí),防火卷簾迫降。
The combination of Smoke detector and Smoke detector ensures the reliability of fire shutter forced landing from the control method. Some design units set Smoke detector or temperature detector at each of the multiple fire shutter. When the detector moves, the fire shutter makes a forced landing.
或者防火卷簾旁邊的任何探測器接到信號(hào)后,卷簾全部迫降地面。這種控制方法也是不合理的。為了及時(shí)控制火勢,防止火災(zāi)蔓延到其他部位,減少火災(zāi)損失,防火卷簾應(yīng)能時(shí)關(guān)閉。那么您知道防火卷簾的正確控制方法嗎?下面
濟(jì)南防火卷簾門安裝維修人員為您講解:
Or after any detector next to the fire shutter receives a signal, all the curtains will be forced to land to the ground. This control method is also unreasonable. In order to control the fire in a timely manner, prevent the fire from spreading to other parts, and reduce fire losses, the fire shutter should be able to close promptly. Do you know the correct control method for fire resistant rolling shutters? The installation and maintenance personnel of Jinan fire Roller shutter will explain to you:
1、當(dāng)防火分區(qū)內(nèi)的任何一個(gè)火災(zāi)探測器檢測到火災(zāi)信號(hào)時(shí),防火分區(qū)內(nèi)的所有防火卷簾都會(huì)同時(shí)迫降。
1. When any fire detector in the fire compartment detects a fire signal, all fire rolling shutters in the fire compartment will make a forced landing at the same time.
2、如果安裝在疏散走道上的防火卷簾安裝在防火分區(qū)內(nèi),應(yīng)在卷簾兩側(cè)附近安裝溫度探測器,或在防火分區(qū)內(nèi)增加幾個(gè)溫度探測器。這樣既能有效地將火勢控制在一定范圍內(nèi),又能防止走道上的防火卷簾過早下降,影響人員疏散。
2. If the fire shutter installed on the evacuation aisle is installed in the fire compartment, temperature detectors should be installed near both sides of the shutter, or several temperature detectors should be added in the fire compartment. This not only effectively controls the fire within a certain range, but also prevents the fire shutter on the aisle from falling too early and affecting personnel evacuation.
3、自動(dòng)扶梯處防火卷簾的迫降方式應(yīng)采用“兩步迫降”,避免自動(dòng)扶梯上的人員因防火卷簾過早迫降而無法及時(shí)疏散到樓層。
3. The forced landing method of the fire resistant roller shutter at the escalator should adopt a "two-step forced landing" to prevent personnel on the escalator from being unable to evacuate safely to the floor in a timely manner due to the early forced landing of the fire resistant roller shutter.
4、毫無疑問,防火卷簾的防火分隔功能可以科學(xué)合理地利用控制探測器的消防設(shè)計(jì)方案,使建筑消防設(shè)施的維護(hù)管理更加完善,從而正確保證防火卷簾門的功能。
4. There is no doubt that the fire separation function of the fireproof rolling shutter can scientifically and reasonably use the fire protection design scheme of the control detector to make the maintenance and management of the building's fire protection facilities more perfect, so as to correctly ensure the function of the fireproof Roller shutter.
防火卷簾的正確控制方法相關(guān)事項(xiàng)就講解到這里了,希望您看完之后能夠有一個(gè)好的使用,更多關(guān)于防火卷簾門的疑惑或者需求,就來我們網(wǎng)站
http://luoboyy.com進(jìn)行咨詢了解吧!
So far are the matters related to the correct control method of the fireproof rolling shutter. I hope you can have a good use after reading it. For more questions or needs about the fireproof Roller shutter, please come to our website http://luoboyy.com Consult and learn more!